Dell AP8858NA3 20-Outlets PDU
Dell AP8858NA3 20-Outlets PDU - Metered - NEMA L6-20P - 18 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 8.86 ft Cord Length - 0U - Rack-mountable
GPC-payable · TAA-compliant configuration on request · usually back within one business day.
- Product Type
- PDU
- Receptacle Type
- IEC 60320 C13
- Receptacle Type
- IEC 60320 C19
- PDU Type
- Metered
- Product Color
- Black
- Receptacle Detail
- 18 x IEC 60320 C13
- Receptacle Detail
- 2 x IEC 60320 C19
- Environmental Compliance
- Restriction of Hazardous Substances (RoHS)
Overview
Dell AP8858NA3 20-Outlets PDU - Metered - NEMA L6-20P - 18 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 8.86 ft Cord Length - 0U - Rack-mountable (part number A4095054) is supplied by Uniqcli, an authorized Dell Technologies partner, in the Dell PDUs category. Input Frequency: 60 Hz Hz.
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency. Local and web-based monitoring. Status available to customers both in the data center and remotely Local Current Monitoring Display. The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip Load indicator LED. Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits Alarm Thresholds. Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems Wide range of input and output connections. Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip
• PDU distributes AC power to multiple servers and balances the load on the servers • You can always avoid potential overloads with PDU meter • IEC 60320 C13 receptacle type to ensure maximum dependability and optimal performance • NEMA L6-20P plug/connector type for reliable, productive connectivity and optimal power output • 230 V AC input voltage for optimal performance with maximum usability
Key specifications: Input Frequency: 60 Hz Hz · Input Current: 20 A A · Input Voltage: 230 V AC · Output Voltage: 208 V AC · Receptacle Type: IEC 60320 C13, IEC 60320 C19 · Load Capacity (Watt): 3300 W W · PDU Type: Metered · Receptacle Detail: 18 x IEC 60320 C13, 2 x IEC 60320 C19.
GPC-payable and available on GSA and government contract vehicles. Ask us about TAA-compliant configurations, current pricing, stock, and lead time.
Tech specs
Power Description
- Input Frequency
- 60 Hz Hz
- Input Current
- 20 A A
- Input Voltage
- 230 V AC
- Output Voltage
- 208 V AC
Technical Information
- Receptacle Type
- IEC 60320 C13, IEC 60320 C19
- Load Capacity (Watt)
- 3300 W W
- PDU Type
- Metered
- Receptacle Detail
- 18 x IEC 60320 C13, 2 x IEC 60320 C19
- Plug/Connector Type
- NEMA L6-20P
- Features
- LED Display
Environmental Conditions
- Minimum Operating Temperature
- 41°F (5°C) °F
- Maximum Operating Temperature
- 113°F (45°C) °F
- Minimum Operating Humidity
- 5% %
- Maximum Operating Humidity
- 95% %
Interfaces/Ports
- Network (RJ-45)
- Yes
Miscellaneous
- Environmental Compliance
- Restriction of Hazardous Substances (RoHS)
- Application/Usage
- Data Center, IT Equipment
- Package Contents
- AP8858NA3 20-Outlets PDU Power Cable - Integrated - 2.7 m Serial Cable - External Rack Mounting Kit
Management
- Management
- SNMP Telnet HTTP
Warranty
- Limited Warranty
- 2 Year Year
Physical Characteristics
- Product Color
- Black
- Cord Length
- 8.86 ft mm
- Height
- 35.5" mm
- Width
- 2.2" mm
- Depth
- 1.7" mm
- Rack Height
- 0U
- Mount Type
- Rack-mountable
- Weight (Approximate)
- 6.39 lb g
General Information
- Product Type
- PDU
- Product Model
- AP8858NA3